NIDisk User Guide
21
1. If the I/O device is not present or is not named "Dev1", NIDisk issues the following
message:
If the device is not present, install it as described in Appendix C of the SIGNAL
Reference Guide. If it is present, open Measurement & Automation Explorer (MAX)
as described under "Confirm and troubleshoot I/O card and driver installation" in
Appendix C and verify that the device is named "Dev1" (see figure). If not, R-click
and rename.
2. If the I/O device is present but NIDisk does not recognize it, NIDisk issues the
following message:
Removable I/O devices, such as PCMCIA cards and USB units, usually need to be
removed and reinserted after the system is restored from Standby, even though
Device Manager may report the device as installed and "working properly". If
the I/O device is removable, remove and reinsert the device. If NIDisk still does not
recognize the device, proceed to step 4.
3. If NIDisk recognizes the I/O device but will not perform I/O operations, select I/O |
Reset on the menu to reset NIDisk status. See "I/O Reset". If NIDisk still will not
perform I/O operations, proceed to the next step.